Skip to content
Industrial flanges Mumbai, India
Valtron Forge & Fittings

Dimensional reference guide

Flange Standards & Dimensions

Identify the full standard, edition, flange type and rating. Similar nominal sizes do not guarantee a matching connection.

These references help define an enquiry; they are not a declaration of stock, certification or suitability for a particular service.

Browse flange types
01

ASME B16.5

An ASME B16.5 enquiry identifies the flange type, nominal size, class, material and facing under the specified edition. The standard name alone does not define a complete joint.

View guide
02

ASME B16.47

ASME B16.47 covers large-diameter steel flange requirements within its defined scope. Every enquiry must distinguish Series A from Series B.

View guide
03

ASME B16.47 Series A

Specify Series A explicitly when ordering a large-diameter flange to ASME B16.47. A matching nominal size does not make a Series B flange interchangeable.

View guide
04

ASME B16.47 Series B

Series B is a separate large-diameter flange series within ASME B16.47. Confirm its complete interface before ordering replacements or mating equipment.

View guide
05

ASME B16.36

ASME B16.36 is the flange reference for orifice-flange arrangements within its scope. It does not replace the design of the differential-pressure metering system.

View guide
06

ASME B16.48

ASME B16.48 addresses operational line blanks within its scope. Distinguish a spectacle blind, a separate spade and a ring spacer from a bolted blind flange.

View guide
07

MSS SP-44

MSS SP-44 is a steel pipeline flange reference. Specify the edition and project design requirements rather than treating it as a universal synonym for another flange standard.

View guide
08

EN 1092-1

EN 1092-1 flange enquiries use a steel flange type, DN and PN designation together with the exact material and facing requirements.

View guide
09

DIN

DIN describes a standards system, not one flange specification. A DIN flange enquiry needs the full standard number, edition and dimensional designation.

View guide
10

BS 4504

BS 4504 is a legacy flange reference that needs its full designation and contractual context. Confirm whether the project requires the original dimensions or a specified successor standard.

View guide
11

BS 10

BS 10 flange enquiries must state the applicable table as well as the nominal size. A table designation is not interchangeable with an ASME class or a PN label.

View guide
12

AWWA C207

AWWA C207 flange enquiries concern steel pipe flanges for waterworks service within the standard scope. Its class designations should not be treated as ASME classes.

View guide
13

API 6A

API 6A flange connections belong to wellhead and tree equipment requirements. They are not general pipe flanges or a modern name for historical API 605 flanges.

View guide
14

JIS

A JIS flange enquiry needs the complete standard number and edition, not only a nominal size and a K designation.

View guide
15

SANS 1123 / SABS 1123

State the required SANS 1123 designation and edition, or the exact historical SABS reference where specified. Current and legacy names should be reconciled in the enquiry.

View guide
16

GOST

GOST is a standards family. A flange enquiry requires the exact GOST number, edition and designation to identify the intended connection.

View guide
17

AS 2129

AS 2129 flange enquiries must specify the applicable table, material and connection form. Table designations cannot be replaced with an assumed PN or ASME class.

View guide
18

UNI

UNI identifies a standards system, not one universal flange design. State the full UNI number, edition and flange designation for a useful enquiry.

View guide

From specification to enquiry

A connection starts with the right details.

Send your material, size, rating, facing and quantity. Include a drawing reference for non-standard requirements.

Discuss Your Requirement

Dimensions and connection data

Define Flange Standards & Dimensions as part of the complete joint. These fields identify required engineering data; they are not universal dimensions or a declaration of available sizes.

Flange Standards & Dimensions: dimensions and connection data
Parameter / designationTechnical informationSelection requirement
Nominal size and boreState the nominal connection size separately from the actual bore or pipe outside diameter.A matching size label does not establish matching internal geometry.
Outside diameter and thicknessIdentify the finished flange diameter, minimum thickness and any hub or collar projection.Include the drawing datum and units for replacement measurements.
Bolt circle and holesRecord pitch-circle diameter, hole quantity, hole diameter and any special orientation.Check against the mating flange; do not infer a bolt pattern from pressure class alone.
Gasket-contact surfacesSpecify face form, seating dimensions and surface finish on the assembled joint.Include gasket designation; a visually similar surface is not evidence of compatibility.
Pipe-side interfaceIdentify weld preparation, socket, thread, collar or other attachment geometry as applicable.Provide pipe schedule/wall thickness and the connection-specific standard.
Design conditionsState design pressure, minimum/maximum temperature, fluid and mechanical loads.Pressure class is not a pressure value in bar or psi. Use the material-specific rating basis.

Compare related options

Compare Flange Standards & Dimensions with the related forms or references below. A related product is not necessarily a permissible substitute.

Flange Standards & Dimensions: compare related options
Related product / referenceDistinctionCheck before selection
ASME B16.5 FlangesAn ASME B16.5 enquiry identifies the flange type, nominal size, class, material and facing under the specified edition. The standard name alone does not define a complete joint.ASME B16.5 edition, flange type, NPS and class
ASME B16.47 FlangesASME B16.47 covers large-diameter steel flange requirements within its defined scope. Every enquiry must distinguish Series A from Series B.Explicit Series A or Series B designation
ASME B16.47 Series A FlangesSpecify Series A explicitly when ordering a large-diameter flange to ASME B16.47. A matching nominal size does not make a Series B flange interchangeable.ASME B16.47 edition with Series A stated
ASME B16.47 Series B FlangesSeries B is a separate large-diameter flange series within ASME B16.47. Confirm its complete interface before ordering replacements or mating equipment.ASME B16.47 edition and Series B
ASME B16.36 FlangesASME B16.36 is the flange reference for orifice-flange arrangements within its scope. It does not replace the design of the differential-pressure metering system.B16.36 edition, configuration, size, class and material
ASME B16.48 Line BlanksASME B16.48 addresses operational line blanks within its scope. Distinguish a spectacle blind, a separate spade and a ring spacer from a bolted blind flange.Spectacle blind, spade or ring spacer

Inspection, documents and delivery

Define acceptance requirements for Flange Standards & Dimensions in the purchase order. Required examinations and documents depend on the material, design and project specification.

Flange Standards & Dimensions: inspection, documents and delivery
Review stageInformation to confirmOrder requirement
Material identity and traceabilitySpecification, grade, heat/lot identification and the required material certificate.Agree documentation and marking before manufacture; visual appearance cannot verify alloy identity.
Dimensional verificationCritical dimensions from the selected standard or controlled drawing.Identify inspection points, tolerances, units and drawing revision.
Surface and end conditionGasket-contact surface, attachment end, edges and any coating exclusions.State finish and visual acceptance criteria; agree protection of machined surfaces.
Supplementary examinationsAny specified PMI, NDE, hardness, impact, corrosion or other tests.Define the method, sampling and acceptance criteria; tests are not automatically included.
Assembly compatibilityAdjoining components, weld or mechanical interface and project service conditions.Design approval and correct assembly remain separate from a dimensional inspection report.
Packing and order releaseQuantity, identification, surface protection, documents and delivery destination.Agree preservation, packaging and release requirements with the order.